DOERS TECHNOLOGY CORPORATION · SINCE 1977Technical support 02-2268-2689
TECHNOLOGYYOUR PROCESS. OUR EXPERTISE.
繁中
615 Series Compact Metal-Tube Flow Meters for Low Flow Rates
Flow
615 Series

Compact Metal-Tube Flow Meters for Low Flow Rates

The 615 compact metal-tube variable-area flow meter provides local indication and optional alarms for low flows of liquids, gases or steam. Provide the fluid, flow range, temperature, pressure, density and viscosity so we can confirm the scale and wetted materials.

Model
615 Series
Category
Flow
SPECIFICATIONS

Technical specifications

ParameterSpecificationUnit
Turndown ratio10:1
Indication accuracyStandard ±2.0% of full scale; optional ±1.5% of full scale
Standard operating temperature−20 to +120°C
Standard pressure rating≤10kgf/cm²G
Meter-tube material options304, 316 or 316L stainless steel, or PTFE lining
Optional alarmInductive proximity switch with a compatible signal interface

Application and selection notes

  • Full-scale accuracy is not the same as percent-of-reading accuracy.
  • For gases or steam, specify operating temperature and pressure and the reference conditions for the flow units.
  • High-temperature, high-pressure and lined versions require individual review; maximum option ratings cannot be combined.

Verify specifications and options against the documents for your model. Select a technical sheet to enlarge it.

DOWNLOADS

Documents

615 Series Technical datasheetPDF · Opens in a new tab
Open PDF ↗
TECHNICAL GUIDES

Explore the principles behind your selection

Choosing flow meters for water, oils, chemicals, gases and steam →From tanks to pipelines: where level, flow and control instruments fit →
APPLICATION SUPPORT

Need help selecting for your application?

Bring your fluid, temperature, pressure, installation and signal requirements to our technical team.

Level and flow measurement planning →